Spirit 2K
Spirit 2K
Overview
- High-frequency switching technology for compact size and light weight
- Pure sine wave output for wide range of applications and harsh environment
- Built-in solar charger controller with MPPT technology to optimize the power utilization
- High efficient DC to AC conversion minimizing energy loss
- Standby charging mode enables battery charging even when the unit is switched off
- Intelligent cooling fan control
- Input/output isolated design for the maximum operation safety
- LCD displays comprehensive operation status
- Configurable AC input voltage range and priority for AC input or PV input
- Support home appliances/Office Equipment/Motor based equipment such as fan, air conditioner, washing machines
- Thorough protections: Input low voltage / Overload / Short circuit / Low battery alarm / Input over voltage / Over tempreature
- Supports both rack and well-mounting set-up for flexible installation
Specifications
| Rating | 2KW/2KVA-24VDC |
| Input | : |
| Input Voltage Waveform | Sinusoidal (Utility or generator) |
| Nominal Input Voltage | 230 Vac |
| Low Loss Voltage | 170Vac±7V (UPS) 90Vac±7V (Appliances) |
| Low Loss Return Voltage | 180Vac±7V (UPS) 100Vac±7V (Appliances) |
| High Loss Voltage | 280Vac±7V |
| High Loss Return Voltage | 270Vac±7V |
| Max AC Input Voltage | 300Vac |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) |
| 50Hz / 60Hz (Auto detection) | 40Hz±1 Hz |
| Low Loss Return Frequency | 42Hz±1 Hz |
| High Loss Frequency | 65Hz±1 Hz |
| High Loss Return Frequency | 63Hz±1 Hz |
| Output | : |
| Output Short Circuit Protection | Breaker |
| High Loss Frequency | <95% (Rated R load, battery full charged) |
| High Loss Return Frequency | 10ms typical (UPS) / 20ms typical (Appliances) |
| INVERTER MODE SPECIFICATONS | : |
| Rated Output Power | 2KW/2KVA |
| Input | : |
| Cold Start Voltage | 23.0Vdc |
| Low DC Warning Voltage | 22.0Vdc © load < 20% / 21.4Vdc © load > 20% |
| Low DC Warning Return Voltage | 23.0Vdc © load < 20% / 22.4Vdc CP load > 20% |
| Low DC Cut-off Voltage | 21.0Vdc © load < 20% / 20.0Vdc CO load > 20% |
| High DC Recovery Voltage | 31.0 Vdc |
| High DC Cut-off Voltage | 32.0 Vdc |
| THDV | <3% for linear load, <5% for non- linear load © nominal voltage |
| DC Offset | <100mV |
| Output | : |
| Output Voltage Waveform | Pure Sine Wave |
| Output Voltage Regulation | 230Vac±5% |
| Output Frequency | 50Hz |
| Peak Efficiency | Peak Efficiency |
| Overload Protection | 5s@150% load; 10s@110%-150% load |
| Surge Capacity | 2 x rated power for 5 seconds |